Xunke Testing specializes in: Shenzhen testing institutions, reliability testing, COC certification, third-party certification bodies, connector testing, third-party test reports, CE certification, material testing, anti-corrosion grade testing, SAA certification, HAST testing, REACH certification, salt spray testing, WF2 corrosion testing, oven testing, acceptance reports, 3C certification inquiry, auto parts testing, ISTA packaging testing, Shenzhen certification bodies, waterproof and dustproof testing, UL certification, 3C certification certificates, water quality testing centers, chemical safety data sheets, stainless steel grade identification, US FDA certification, MSDS inquiry, material analysis, metal material grade identification, MIC certification, MSDS, hazardous substance testing, software testing, hardness testing, paint and coating testing, UV aging testing, material performance testing, three-comprehensive testing, third-party testing institutions, aluminum alloy testing, grade identification, EMC electromagnetic compatibility testing, stainless steel testing, quality inspection reports, metal material analysis, sulfur dioxide corrosion testing, MTBF test reports, Shenzhen testing centers, biodegradation testing, building materials testing, toy testing, noise testing, HALT testing, cable testing, acoustic testing, IP protection rating testing, MSDS reports, FDA certification, product life testing, packaging and transportation testing, software evaluation, Amazon test reports, xenon lamp aging testing, FDA registration, thermal shock testing, gas corrosion testing, rapid temperature change testing, steel testing, MTBF test reports, heavy metal testing, MSDS certification, WiFi certification, model approval, mechanical CE certification, VCCI certification, Japan JATE certification, Qi certification, ETL certification, ROHS certification, KC certification, explosion-proof certification, MTBF certification, Bluetooth BQB certification, CB certification, CE certification bodies, IC certification, 3C certification bodies, building materials CE certification, NCC certification, CE certification companies, WPC certification, HDMI certification, BIS certification, EU CE certification, SRRC certification, CQC, 3C certification, CCC certification, PSE certification, FCC certification, KCC certification, carton transportation testing, failure analysis, battery testing, TDS reports, CE certification costs, REACH regulations, third-party quality inspection reports, carton testing and other products and services. Consultation hotline: 0755-23727890.

Consultation Hotline: 0755-23727890,23312011 /400-669-8118

Wireless Products in the EU: Cybersecurity and EMC Testing Under the RED Directive

1. Regulatory Overview

The Radio Equipment Directive 2014/53/EU covers electrical and electronic products that intentionally or unintentionally emit radio waves. It combines electrical safety, electromagnetic compatibility, efficient use of the radio spectrum and, for defined categories, cybersecurity. The cybersecurity essential requirements in Article 3(3)(d), (e) and (f) were made applicable by Delegated Regulation (EU) 2022/30, as amended by Delegated Regulation (EU) 2023/2444, from 1 August 2025.

The harmonised standards EN 18031-1:2024, EN 18031-2:2024 and EN 18031-3:2024 were cited in the Official Journal by Commission Implementing Decision (EU) 2025/138, with restrictions. From 11 September 2026, the Cyber Resilience Act, Regulation (EU) 2024/2847, adds reporting duties for actively exploited vulnerabilities and severe incidents. From 11 December 2027, the CRA's main obligations apply and the RED delegated cybersecurity framework is repealed for the products concerned.

2. Product Scope and Associated Standards

RequirementApplicable product groupTypical harmonised standard
Network protection, Article 3(3)(d)Internet-connected radio equipmentEN 18031-1:2024
Personal data and privacy, Article 3(3)(e)Internet-connected equipment, childcare equipment, radio toys and wearables processing personal dataEN 18031-2:2024
Fraud protection, Article 3(3)(f)Radio equipment allowing transfer of money, monetary value or virtual currencyEN 18031-3:2024
EMC emissionMultimedia and information technology equipmentEN 55032:2015+A11:2020
EMC immunityMultimedia equipmentEN 55035:2017+A11:2020
Mains harmonic and flickerEquipment connected to the public mainsEN 61000-3-2 and EN 61000-3-3, current cited editions
Electrical safetyAudio, video, information and communication technology equipmentEN IEC 62368-1:2020+A11:2020

3. Core Test Items

DomainWhat is examinedKey detail
CybersecurityAsset inventory, authentication, secure update, logging, network behaviourThe Official Journal restrictions remove the presumption of conformity if the no-password option in clauses 6.2.5.1 or 6.2.5.2 is used
PrivacyPersonal data protection, parental or guardian access control where applicableEN 18031-2 restrictions apply to certain equipment classes if access control is not ensured
FraudTransaction integrity and protection of monetary or virtual valueEN 18031-3 applies where the device handles value transfer
EMCConducted and radiated emission, immunity to disturbancesUse the exact OJ-cited edition of EN 55032 and EN 55035
RadioFrequency, power, spectrum access and spurious emissionsSelect the radio standard relevant to the technology and band
SafetyElectric shock, energy hazards and fire riskAlign with LVD-style safety assessment where the product is in scope

4. Assessment Workflow

  • Determine whether the device is internet-connectable, processes personal data, or supports value transfer; more than one EN 18031 part may apply.
  • Check the Official Journal citation and all restrictions. If a restriction removes the presumption of conformity, involve a notified body for that requirement.
  • Build the security asset list and map each asset to the applicable clause of EN 18031-1, -2 or -3.
  • Run EMC testing to the cited editions of EN 55032 and EN 55035, plus mains disturbance standards where applicable.
  • Run radio testing to the applicable ETSI standard and assess RF exposure and electrical safety.
  • Compile the RED technical file, issue the EU DoC referencing every applicable act and standard, and affix the CE marking with the notified body number if one is involved.
  • From 11 September 2026, operate a reporting process for actively exploited vulnerabilities and severe incidents under the CRA.

5. Documentation and Marking Control

Keep the cybersecurity risk assessment, architecture description, test evidence, software version record and restriction analysis in the technical file. For CRA readiness, add a vulnerability contact point, an inventory of components and a defined support period. The DoC must identify the product, the manufacturer, the applicable EU acts, the standards used and the authorised signatory.

6. Application Scenarios

  • Smart home devices using Wi-Fi, Bluetooth, Zigbee or a gateway connection.
  • Wearables and connected toys that process personal or location data.
  • Industrial controllers with a radio interface and remote maintenance access.
  • Payment or value-transfer terminals with wireless connectivity.
  • Products already on the EU market preparing for CRA reporting from 11 September 2026.

7. Common Questions

When did RED cybersecurity become mandatory?

The requirements in Delegated Regulation (EU) 2022/30 apply from 1 August 2025 to the categories defined in the delegated act.

Which EN 18031 part applies to my device?

EN 18031-1 covers network protection, EN 18031-2 covers personal data and privacy, and EN 18031-3 covers fraud protection. A device may need more than one part.

Does using EN 18031 always avoid notified body involvement?

Not if an Official Journal restriction removes the presumption of conformity for the implemented design. Check the restrictions carefully, especially around passwords and access control.

Which EMC standards are normally cited?

For multimedia equipment, EN 55032:2015+A11:2020 for emission and EN 55035:2017+A11:2020 for immunity are cited under the EMC framework; verify the current Official Journal list.

What changes on 11 September 2026?

CRA reporting obligations apply: actively exploited vulnerabilities and severe incidents must be reported through the designated channel within the set timelines.

What changes on 11 December 2027?

The CRA's main obligations apply, including secure-by-design requirements, technical documentation, conformity assessment and CE marking for products with digital elements.

Can an old EMC report be reused?

Only if the cited edition still supports the current essential requirements and the tested configuration matches the product being placed on the market.

8. Closing Note and Disclaimer

For radio products, compliance is a combination of radio, EMC, safety and cybersecurity evidence under RED and, increasingly, the CRA.

The methods and results described in this article are provided for general technical reference only. They do not constitute a conformity decision, a conclusion on the consistency of a batch or later batches, a certification, acceptance, grading or product-selection conclusion. Results obtained under defined test conditions do not reproduce actual service conditions or long-term field performance, and accelerated or short-term laboratory data are not converted into a service life.

Each legal act and standard cited has its own scope: product legislation sets the framework, harmonised standards give test methods, and the two should not be substituted for each other. Scope, test conditions, acceptance criteria and standard versions should be verified against the current valid texts and the technical agreement. Provisions that have been published but have not yet entered into application should not be used as a basis for a present-day conformity decision.