Xunke Testing specializes in: Shenzhen testing institutions, reliability testing, COC certification, third-party certification bodies, connector testing, third-party test reports, CE certification, material testing, anti-corrosion grade testing, SAA certification, HAST testing, REACH certification, salt spray testing, WF2 corrosion testing, oven testing, acceptance reports, 3C certification inquiry, auto parts testing, ISTA packaging testing, Shenzhen certification bodies, waterproof and dustproof testing, UL certification, 3C certification certificates, water quality testing centers, chemical safety data sheets, stainless steel grade identification, US FDA certification, MSDS inquiry, material analysis, metal material grade identification, MIC certification, MSDS, hazardous substance testing, software testing, hardness testing, paint and coating testing, UV aging testing, material performance testing, three-comprehensive testing, third-party testing institutions, aluminum alloy testing, grade identification, EMC electromagnetic compatibility testing, stainless steel testing, quality inspection reports, metal material analysis, sulfur dioxide corrosion testing, MTBF test reports, Shenzhen testing centers, biodegradation testing, building materials testing, toy testing, noise testing, HALT testing, cable testing, acoustic testing, IP protection rating testing, MSDS reports, FDA certification, product life testing, packaging and transportation testing, software evaluation, Amazon test reports, xenon lamp aging testing, FDA registration, thermal shock testing, gas corrosion testing, rapid temperature change testing, steel testing, MTBF test reports, heavy metal testing, MSDS certification, WiFi certification, model approval, mechanical CE certification, VCCI certification, Japan JATE certification, Qi certification, ETL certification, ROHS certification, KC certification, explosion-proof certification, MTBF certification, Bluetooth BQB certification, CB certification, CE certification bodies, IC certification, 3C certification bodies, building materials CE certification, NCC certification, CE certification companies, WPC certification, HDMI certification, BIS certification, EU CE certification, SRRC certification, CQC, 3C certification, CCC certification, PSE certification, FCC certification, KCC certification, carton transportation testing, failure analysis, battery testing, TDS reports, CE certification costs, REACH regulations, third-party quality inspection reports, carton testing and other products and services. Consultation hotline: 0755-23727890.

Consultation Hotline: 0755-23727890,23312011 /400-669-8118

Wrong CE Mark Size or Placement? EU Testing and Marking Rules Explained

1. Regulatory Overview

The CE marking is a visible result of a conformity assessment, not a quality mark and not a substitute for the EU Declaration of Conformity. The general design and affixing rules come from Decision No 768/2008/EC and are summarised in the European Commission guidance: the mark consists of the initials CE, both letters have the same vertical dimension, the minimum height is 5 mm unless product rules specify otherwise, proportions are preserved if resized, and the mark must be visible, legible and indelible.

A marking error can undermine an otherwise complete technical file. If the mark is not affixed correctly, or if it is used on a product outside the scope of a CE-marked act, the declaration and the physical product no longer tell the same story. Market surveillance authorities and customs may then request corrective action.

2. Common Size and Placement Errors

ErrorWhy it mattersTypical correction
Letters with different vertical dimensionsBreaks the prescribed CE formUse the official drawing and check both letters
Height below 5 mm where no product rule allows itFails the minimum size requirementEnlarge the mark or justify the exception in the product rules
Stretched or compressed logoProportions are not preservedRegenerate from the official vector file
Mark only on the shipping cartonThe product can bear the mark, so the product should carry itAdd the mark to the product or data plate
Missing notified body four-digit numberRequired when a notified body is involved in production controlPlace the number next to the CE mark
CE used on a non-covered productMisleading and not legally recognisedRemove the mark and apply general product safety rules instead
Mark applied before assessment is completePremature declaration of conformityComplete assessment, DoC and technical file first

3. Correct Marking Rules

  • Affix the CE marking before the product is placed on the market and only after all applicable conformity steps are complete.
  • Place it directly on the product or its data plate. If the nature of the product makes that impossible, place it on the packaging and accompanying documents.
  • Keep the mark visible, legible and indelible under normal handling and use.
  • If several EU acts apply, the accompanying documents must confirm compliance with all of them.
  • When a notified body is involved in the production control phase, include its identification number next to the mark.
  • Do not use a voluntary third-party certificate as a substitute for the CE marking process.

4. Verification Methods

  • Artwork check: compare the label file with the official CE drawing, including proportions and letter height.
  • Measurement check: measure the vertical dimension on a printed sample with a calibrated instrument and record the result.
  • Durability check: rub or wipe the marked area under the intended handling conditions and confirm the mark remains legible.
  • Placement check: confirm the mark is on the product or data plate, not only on the outer package, unless an exception applies.
  • Document check: verify that the DoC lists every applicable act and that the technical file supports the marked configuration.
  • Notified body check: confirm the four-digit number matches the body authorised for the procedure used.

5. Documentation and Record Control

Label artwork approval should be part of the technical file change control. Record the mark version, drawing source, supplier, print date and the model or serial range. Keep the signed DoC, test reports and the label evidence together so a market surveillance request can be answered with a consistent set of documents.

6. Application Scenarios

  • New product launch where artwork is finalised before the test report is issued.
  • Rebranding or repackaging by a distributor that changes the original CE label.
  • Multi-directive products such as radio equipment also subject to EMC and RoHS rules.
  • Online marketplace listings where the product photo must show the actual marking.

7. Common Questions

What is the minimum CE mark height?

The general rule is 5 mm unless the product-specific rules state otherwise. If the mark is reduced or enlarged, the proportions of the official drawing must be preserved.

Can the mark be placed only on the packaging?

Only where the nature of the product makes affixing on the product impossible or not warranted. Otherwise the product or its data plate should carry the mark.

Does the CE mark need to be printed in black?

No. It may appear in different styles such as colour, solid or hollow, as long as it remains clear, visible, legible and indelible.

When must the notified body number appear?

When a notified body is involved in the production control phase. The four-digit number must be placed next to the CE marking.

Can a supplier put the CE mark on my product?

The manufacturer remains responsible. A supplier label does not transfer the legal responsibility for conformity or for correct marking.

Is the CE mark a quality certificate?

No. It is a declaration that the product met the applicable EU requirements at the time it was placed on the market.

What if several EU acts apply?

All applicable acts must be met, and the accompanying documents must confirm compliance with each of them before the mark is affixed.

8. Closing Note and Disclaimer

Correct CE marking depends on the applicable act, the current harmonised standards and the physical label; one of these elements out of step can weaken the whole declaration.

The methods and results described in this article are provided for general technical reference only. They do not constitute a conformity decision, a conclusion on the consistency of a batch or later batches, a certification, acceptance, grading or product-selection conclusion. Results obtained under defined test conditions do not reproduce actual service conditions or long-term field performance, and accelerated or short-term laboratory data are not converted into a service life.

Each legal act and standard cited has its own scope: product legislation sets the framework, harmonised standards give test methods, and the two should not be substituted for each other. Scope, test conditions, acceptance criteria and standard versions should be verified against the current valid texts and the technical agreement. Provisions that have been published but have not yet entered into application should not be used as a basis for a present-day conformity decision.

Copyright Shenzhen Xunke Standard Technical Services Co., Ltd. 粤ICP备16026918No.-1


Sitemap XML
Content of class "zhezhoceng" is displayed here
Get a Quote
Company Name: * Your Name: * Your Mobile: * Your Requirements: *